Top Line: Dose the minimum dose to the PTV affect the risk of local failure after spine SBRT?
The Study: Spine SBRT provides superior pain control and local control when compared to conventional palliative radiation. When planning spine SBRT, we typically have to sacrifice some target volume coverage in order to meet spinal cord dose constraints. Does undercoverage of the PTV increase the risk of recurrence? This large retrospective series evaluated clinical and dosimetric predictors of local failure after spine SBRT. It included 377 patients who received 522 SBRT treatments. Patients were treated with mostly a single fraction (68%) of 20-24 Gy to the gross tumor volume and 16 Gy to the PTV, but some also received 21-24 Gy in 3 fractions with a simultaneous integrated boost of 27-36 Gy to the GTV. The targets were delineated according to consensus guidelines. In planning, they limited dose to the true spinal cord structure rather than the thecal sac or a PRV. The cord was limited to 14 Gy to 0.03cc and V10<10% for a single fraction. The rate of local failure was 10.6% at 1 year and 16.3% at 2 years. They found that the optimal minimum PTV dose was 15.3 Gy in 1 fraction. Above this, the rate of local failure was 6.1% at 1 year compared to 14.2% when the minimum dose fell below 15.3 Gy. Similar results were found when 14 Gy (the spinal cord maximum dose) was used as a cutpoint. Soft tissue extension and epidural extension were also significantly associated with local failure risk. This raises the question of how best to approach epidural disease abuting the spinal cord. The results suggest that covering the PTV with at least the maximum spinal cord dose is associated with better local control
TBL: In this retrospective study of mostly single-fraction spine SBRT with simultaneous integrated boost, a minimum single-fraction dose of 14-15.3 Gy to the PTV was associated with better local control. | Kowalchuk, Radiother Oncol 2024
The Study: Spine SBRT provides superior pain control and local control when compared to conventional palliative radiation. When planning spine SBRT, we typically have to sacrifice some target volume coverage in order to meet spinal cord dose constraints. Does undercoverage of the PTV increase the risk of recurrence? This large retrospective series evaluated clinical and dosimetric predictors of local failure after spine SBRT. It included 377 patients who received 522 SBRT treatments. Patients were treated with mostly a single fraction (68%) of 20-24 Gy to the gross tumor volume and 16 Gy to the PTV, but some also received 21-24 Gy in 3 fractions with a simultaneous integrated boost of 27-36 Gy to the GTV. The targets were delineated according to consensus guidelines. In planning, they limited dose to the true spinal cord structure rather than the thecal sac or a PRV. The cord was limited to 14 Gy to 0.03cc and V10<10% for a single fraction. The rate of local failure was 10.6% at 1 year and 16.3% at 2 years. They found that the optimal minimum PTV dose was 15.3 Gy in 1 fraction. Above this, the rate of local failure was 6.1% at 1 year compared to 14.2% when the minimum dose fell below 15.3 Gy. Similar results were found when 14 Gy (the spinal cord maximum dose) was used as a cutpoint. Soft tissue extension and epidural extension were also significantly associated with local failure risk. This raises the question of how best to approach epidural disease abuting the spinal cord. The results suggest that covering the PTV with at least the maximum spinal cord dose is associated with better local control
TBL: In this retrospective study of mostly single-fraction spine SBRT with simultaneous integrated boost, a minimum single-fraction dose of 14-15.3 Gy to the PTV was associated with better local control. | Kowalchuk, Radiother Oncol 2024