Top Line: Lung SBRT is pretty standard at this point, right?
The Study: Well, there is actually quite a bit of variation across centers and around the world when it comes to lung SBRT. This huge international patterns of care survey, which consisted of 35 questions about patients selection, treatment planning, and clinical scenarios, was completed by 255 radiation oncologists representing 255 different centers across 51 countries. The median number of lung SBRT cases per year was 20. Two-thirds (67.5%) had a specific size cutoff for lung SBRT with a mean cutoff of 5.5 cm. Only 21% used IV contrast during simulation. Just over half (53.7%) had a Dmax cutoff with a mean of 130%, and a third (36.1%) actually had a lower limit for Dmax with a mean of 115%. Conformity was specifically measured by 64.7%, and 55.7% used R50% in plan evaluation. Not unexpectedly, prescriptions varied by anatomic location and clinical scenario. For peripheral tumors, the most common prescription was 54 Gy in 3 fractions (39.6%) followed by 48 Gy in 4 fractions (14.5%). Over a third of respondents (38.4%) reported sometimes utilizing single fraction SBRT. For peripheral tumors abutting the chest wall, the most common prescription was 50 Gy in 5 fractions (24.3%) followed by 55 Gy in 5 fractions (18.3%). For central tumors, 50 Gy in 5 fractions was most common (47.2%) followed by 60 Gy in 8 fractions (35.4%). This pattern was reversed for ultracentral tumors (40.7% 60/8, 17.7% 50/5).
TBL: Lung SBRT planning is varied across the world, but most centers use standard, high BED prescriptions based on anatomic location with heterogeneous dose within the target. | Alaifi, Int J Radiat Oncol Biol Phys 2025
The Study: Well, there is actually quite a bit of variation across centers and around the world when it comes to lung SBRT. This huge international patterns of care survey, which consisted of 35 questions about patients selection, treatment planning, and clinical scenarios, was completed by 255 radiation oncologists representing 255 different centers across 51 countries. The median number of lung SBRT cases per year was 20. Two-thirds (67.5%) had a specific size cutoff for lung SBRT with a mean cutoff of 5.5 cm. Only 21% used IV contrast during simulation. Just over half (53.7%) had a Dmax cutoff with a mean of 130%, and a third (36.1%) actually had a lower limit for Dmax with a mean of 115%. Conformity was specifically measured by 64.7%, and 55.7% used R50% in plan evaluation. Not unexpectedly, prescriptions varied by anatomic location and clinical scenario. For peripheral tumors, the most common prescription was 54 Gy in 3 fractions (39.6%) followed by 48 Gy in 4 fractions (14.5%). Over a third of respondents (38.4%) reported sometimes utilizing single fraction SBRT. For peripheral tumors abutting the chest wall, the most common prescription was 50 Gy in 5 fractions (24.3%) followed by 55 Gy in 5 fractions (18.3%). For central tumors, 50 Gy in 5 fractions was most common (47.2%) followed by 60 Gy in 8 fractions (35.4%). This pattern was reversed for ultracentral tumors (40.7% 60/8, 17.7% 50/5).
TBL: Lung SBRT planning is varied across the world, but most centers use standard, high BED prescriptions based on anatomic location with heterogeneous dose within the target. | Alaifi, Int J Radiat Oncol Biol Phys 2025

