Top Line:
The Study: In RTOG 0617, dose escalation to the entire irradiated volume resulted in worse survival for patients with locally advanced NSCLC. The latest generation of trials have sought to escalate dose in a more selective manner. Recently, RTEP7-IFCT-1402 showed a numeric (but not statistically significant) improvement in local control with PET-adaptive dose escalation. RTOG 1106 was a randomized, phase 2 trial that sought to dose-escalate using a mid-treatment PET. It included 127 patients receiving chemoradiation for NSCLC were randomized to the standard 60 Gy in 30 fractions or PET-adapted therapy. In the PET arm, the metabolic target volume (MTV) was defined using a threshold of >1.5 times the SUVmax of the aorta. These patients received 46.2 Gy in 21 fractions (2.2 Gy per fraction). A PET CT was obtained during the 4th week of treatment, and this was used to adapt the target volumes to allow for a boost of up to 34.2 Gy in 9 fractions (3.8 Gy per fraction) for a potential total dose of 80.4 Gy. However, this boost still had to meet OAR constraints including a mean lung dose of 20 Gy or less. There was a median 56% reduction in MTV volume compared to baseline. The median actual dose delivered in the adaptive arm was 71 Gy. At 2 years, there was no improvement in freedom from local progression in the adaptive arm (59.5% v 54.6%). Overall grade 3+ toxicity was similar between arms, but more patients in the adaptive arm had grade 2+ esophagitis (43% v 31%). Another important finding from the study was that PET measures (such as SUVpeak) were not significantly associated with FFLP. In other words, FDG PET doesn’t appear to be a great predictive test for benefit from radiation dose escalation.
TBL: In RTOG 1106, PET-adaptive dose escalation up to 80.4 Gy in 30 fractions did not improve freedom from local progression. | Kong, J Clin Oncol 2024
The Study: In RTOG 0617, dose escalation to the entire irradiated volume resulted in worse survival for patients with locally advanced NSCLC. The latest generation of trials have sought to escalate dose in a more selective manner. Recently, RTEP7-IFCT-1402 showed a numeric (but not statistically significant) improvement in local control with PET-adaptive dose escalation. RTOG 1106 was a randomized, phase 2 trial that sought to dose-escalate using a mid-treatment PET. It included 127 patients receiving chemoradiation for NSCLC were randomized to the standard 60 Gy in 30 fractions or PET-adapted therapy. In the PET arm, the metabolic target volume (MTV) was defined using a threshold of >1.5 times the SUVmax of the aorta. These patients received 46.2 Gy in 21 fractions (2.2 Gy per fraction). A PET CT was obtained during the 4th week of treatment, and this was used to adapt the target volumes to allow for a boost of up to 34.2 Gy in 9 fractions (3.8 Gy per fraction) for a potential total dose of 80.4 Gy. However, this boost still had to meet OAR constraints including a mean lung dose of 20 Gy or less. There was a median 56% reduction in MTV volume compared to baseline. The median actual dose delivered in the adaptive arm was 71 Gy. At 2 years, there was no improvement in freedom from local progression in the adaptive arm (59.5% v 54.6%). Overall grade 3+ toxicity was similar between arms, but more patients in the adaptive arm had grade 2+ esophagitis (43% v 31%). Another important finding from the study was that PET measures (such as SUVpeak) were not significantly associated with FFLP. In other words, FDG PET doesn’t appear to be a great predictive test for benefit from radiation dose escalation.
TBL: In RTOG 1106, PET-adaptive dose escalation up to 80.4 Gy in 30 fractions did not improve freedom from local progression. | Kong, J Clin Oncol 2024